#ifndef FAULTCODE_H #define FAULTCODE_H /** * @file faultCode.h * @brief 锂电池故障码定义及映射表 */ // 故障码映射表 typedef struct { int id; // 序号 int level; // 故障级别 const uint8_t code; // 16进制故障码 const char* desc; // 报警信息 } FaultMap; static const FaultMap batfaultMap[] = { //四级故障 {1, 4, 0xC1, "MBMS绝缘故障"}, {2, 4, 0xC2, "温度过高"}, {3, 4, 0xC3, "MBMS预充失败"}, {4, 4, 0xC4, "MBMS正主极继电器失效"}, {5, 4, 0xC5, "MBMS负主极继电器失效"}, {6, 4, 0xC6, "MBMS燃电充电正极继电器正极失效[仪器]"}, {7, 4, 0xC7, "母线高压回路异常"}, {8, 4, 0xC9, "MBMS电压测量异常"}, {9, 4, 0xCA, "MBMS电流测量异常"}, //三级故障 {10, 3, 0x81, "MBMS绝缘故障3级"}, {11, 3, 0x82, "温度过高3级"}, {12, 3, 0x83, "温度过低3级"}, {13, 3, 0x84, "MBMS总放电超功率3级"}, {14, 3, 0x85, "MBMS总充电电流过大3级"}, //二级故障 {15, 1, 0x31, "BMS均衡模块故障2级"}, {16, 2, 0x41, "MBMS绝缘故障2级"}, {17, 2, 0x42, "MBMS总放电超功率2级"}, {18, 2, 0x43, "电池包放电超功率2级"}, {19, 2, 0x44, "MBMS总放电过流2级"}, {20, 2, 0x45, "单包异常剔除2级"}, {21, 2, 0x46, "单包没有电流2级"}, {22, 2, 0x47, "自检有重复ID号2级"}, {23, 2, 0x48, "电池包接入失败2级"}, {24, 2, 0x49, "电池包充电电流过大2级"}, {25, 2, 0x51, "电池包绝缘故障2级"}, {26, 2, 0x52, "电池包温度过高2级"}, {27, 2, 0x53, "电池包温度过低2级"}, {28, 2, 0x54, "电池包单体电压不均衡2级"}, {29, 2, 0x55, "电池包单体温度不均衡2级"}, {30, 2, 0x56, "电池包过流2级"}, {31, 2, 0x57, "电池包充电电流过大2级"}, {32, 2, 0x58, "电池包单体电压过高2级"}, {33, 2, 0x59, "电池包单体电压过低2级"}, {34, 2, 0x5A, "电池包总电压过高2级"}, {35, 2, 0x5B, "电池包总电压过低2级"}, {36, 2, 0x5C, "电池包内部通讯故障2级"}, {37, 2, 0x5D, "电池包初始化故障2级"}, {38, 2, 0x62, "电池包高压回路连接异常2级"}, {39, 2, 0x65, "电池包烟雾报警2级"}, {40, 2, 0x72, "MBMS在线燃电充电超温2级"}, //一级故障 {41, 1, 0x01, "MBMS绝缘故障1级"}, {42, 1, 0x02, "MBMS总放电超功率1级"}, {43, 1, 0x11, "电池包绝缘故障1级"}, {44, 1, 0x12, "电池包最高温度过高1级"}, {45, 1, 0x13, "电池包最低温度过低1级"}, {46, 1, 0x14, "电池包单体电压不均衡1级"}, {47, 1, 0x15, "电池包单体温度不均衡1级"}, {48, 1, 0x16, "电池包放电过流1级"}, {49, 1, 0x17, "电池包充电电流过大1级"}, {50, 1, 0x18, "电池包单体电压过高1级"}, {51, 1, 0x19, "电池包单体电压过低1级"}, {52, 1, 0x1A, "电池包总电压过高1级"}, {53, 1, 0x1B, "电池包总电压过低1级"}, {54, 1, 0x1D, "电池包烟雾报警1级"}, }; static const FaultMap disfaultMap[] = { {1, 3, 1, "燃料电池断路器故障脱扣"}, {2, 4, 2, "动力锂电池断路器故障脱扣"}, {3, 4, 3, "推进电机断路器故障脱扣"}, {4, 4, 4, "锂电池组仪表断路器故障脱扣"}, {5, 4, 5, "DC/DC5模块断路器故障脱扣"}, {6, 4, 6, "艏部高压配电箱断路器故障脱扣"}, {7, 4, 7, "艉部FT装置4/5断路器故障脱扣"}, {8, 4, 8, "艉舵开关1断路器故障脱扣"}, {9, 4, 9, "艉舵开关2断路器故障脱扣"}, {10, 4, 10, "FB预留断路器故障脱扣"}, {11, 4, 11, "TYZ预留断路器故障脱扣"}, {12, 4, 12, "预留断路器故障脱扣"}, {13, 4, 13, "艏部FT装置1-3 断路器故障脱扣"}, {14, 4, 14, "启闭机构断路器故障脱扣"}, {15, 4, 15, "桅杆舵机控制箱断路器故障脱扣"}, {16, 4, 16, "XCZ 断路器故障脱扣"}, {17, 4, 17, "艏舵控制箱断路器故障脱扣"}, {18, 4, 18, "敞水盖启动电缸断路器故障脱扣"}, {19, 4, 19, "锂电池组(仪表)断路器故障脱扣"}, {20, 4, 20, "艏部低压配电箱断路器故障脱扣"}, {21, 4, 21, "UNIT4仪表DC48V断路器故障脱扣"}, {22, 4, 22, "DC-DC1直流配电板断路器故障脱扣"}, {23, 4, 23, "预留断路器故障脱扣"}, {24, 4, 24, "预留断路器故障脱扣"}, {25, 4, 25, "应急锂电池组2断路器"}, {26, 4, 26, "UNIT1断路器故障脱扣"}, {27, 4, 27, "UNIT2断路器故障脱扣"}, {28, 4, 28, "UNIT3断路器故障脱扣"}, {29, 4, 29, "UNIT5断路器故障脱扣"}, {30, 4, 30, "艏部PZ装置断路器故障脱扣"}, {31, 4, 31, "预留断路器故障脱扣"}, {32, 4, 32, "预留断路器故障脱扣"}, {33, 4, 33, "应急锂电池组1断路器故障脱扣"}, {34, 4, 34, "动力母排绝缘低"}, {35, 4, 35, "A汇流排绝缘低"}, {36, 4, 36, "高压母线配电控制器仪表电源失电信号"}, {37, 4, 37, "高压母线配电控制器应急电源失电信号"}, {38, 4, 38, "高压汇流排A仪表电源失电信号"}, {39, 4, 39, "高压汇流排A应急电源失电信号"}, {40, 4, 40, "高压汇流排A仪表汇流排绝缘低"}, {41, 4, 41, "高压汇流排B仪表电源失电信号"}, {42, 4, 42, "高压汇流排B应急电源失电信号"}, {43, 4, 43, "高压汇流排B仪表汇流排绝缘低"}, {44, 4, 44, "仪表汇流排失电信号"}, {45, 4, 45, "仪表汇流排浸水报警"} }; #endif // FAULTCODE_H