Files
H100PowerManger/src/pPowerManger/faultCode.h
T
2025-05-19 20:42:20 +08:00

126 lines
5.5 KiB
C

#ifndef FAULTCODE_H
#define FAULTCODE_H
/**
* @file faultCode.h
* @brief 锂电池故障码定义及映射表
*/
// 故障码映射表
typedef struct {
int id; // 序号
int level; // 故障级别
const uint8_t code; // 16进制故障码
const char* desc; // 报警信息
} FaultMap;
static const FaultMap batfaultMap[] = {
//四级故障
{1, 4, 0xC1, "MBMS绝缘故障"},
{2, 4, 0xC2, "温度过高"},
{3, 4, 0xC3, "MBMS预充失败"},
{4, 4, 0xC4, "MBMS正主极继电器失效"},
{5, 4, 0xC5, "MBMS负主极继电器失效"},
{6, 4, 0xC6, "MBMS燃电充电正极继电器正极失效[仪器]"},
{7, 4, 0xC7, "母线高压回路异常"},
{8, 4, 0xC9, "MBMS电压测量异常"},
{9, 4, 0xCA, "MBMS电流测量异常"},
//三级故障
{10, 3, 0x81, "MBMS绝缘故障3级"},
{11, 3, 0x82, "温度过高3级"},
{12, 3, 0x83, "温度过低3级"},
{13, 3, 0x84, "MBMS总放电超功率3级"},
{14, 3, 0x85, "MBMS总充电电流过大3级"},
//二级故障
{15, 1, 0x31, "BMS均衡模块故障2级"},
{16, 2, 0x41, "MBMS绝缘故障2级"},
{17, 2, 0x42, "MBMS总放电超功率2级"},
{18, 2, 0x43, "电池包放电超功率2级"},
{19, 2, 0x44, "MBMS总放电过流2级"},
{20, 2, 0x45, "单包异常剔除2级"},
{21, 2, 0x46, "单包没有电流2级"},
{22, 2, 0x47, "自检有重复ID号2级"},
{23, 2, 0x48, "电池包接入失败2级"},
{24, 2, 0x49, "电池包充电电流过大2级"},
{25, 2, 0x51, "电池包绝缘故障2级"},
{26, 2, 0x52, "电池包温度过高2级"},
{27, 2, 0x53, "电池包温度过低2级"},
{28, 2, 0x54, "电池包单体电压不均衡2级"},
{29, 2, 0x55, "电池包单体温度不均衡2级"},
{30, 2, 0x56, "电池包过流2级"},
{31, 2, 0x57, "电池包充电电流过大2级"},
{32, 2, 0x58, "电池包单体电压过高2级"},
{33, 2, 0x59, "电池包单体电压过低2级"},
{34, 2, 0x5A, "电池包总电压过高2级"},
{35, 2, 0x5B, "电池包总电压过低2级"},
{36, 2, 0x5C, "电池包内部通讯故障2级"},
{37, 2, 0x5D, "电池包初始化故障2级"},
{38, 2, 0x62, "电池包高压回路连接异常2级"},
{39, 2, 0x65, "电池包烟雾报警2级"},
{40, 2, 0x72, "MBMS在线燃电充电超温2级"},
//一级故障
{41, 1, 0x01, "MBMS绝缘故障1级"},
{42, 1, 0x02, "MBMS总放电超功率1级"},
{43, 1, 0x11, "电池包绝缘故障1级"},
{44, 1, 0x12, "电池包最高温度过高1级"},
{45, 1, 0x13, "电池包最低温度过低1级"},
{46, 1, 0x14, "电池包单体电压不均衡1级"},
{47, 1, 0x15, "电池包单体温度不均衡1级"},
{48, 1, 0x16, "电池包放电过流1级"},
{49, 1, 0x17, "电池包充电电流过大1级"},
{50, 1, 0x18, "电池包单体电压过高1级"},
{51, 1, 0x19, "电池包单体电压过低1级"},
{52, 1, 0x1A, "电池包总电压过高1级"},
{53, 1, 0x1B, "电池包总电压过低1级"},
{54, 1, 0x1D, "电池包烟雾报警1级"},
};
static const FaultMap disfaultMap[] = {
{1, 3, 1, "燃料电池断路器故障脱扣"},
{2, 4, 2, "动力锂电池断路器故障脱扣"},
{3, 4, 3, "推进电机断路器故障脱扣"},
{4, 4, 4, "锂电池组仪表断路器故障脱扣"},
{5, 4, 5, "DC/DC5模块断路器故障脱扣"},
{6, 4, 6, "艏部高压配电箱断路器故障脱扣"},
{7, 4, 7, "艉部FT装置4/5断路器故障脱扣"},
{8, 4, 8, "艉舵开关1断路器故障脱扣"},
{9, 4, 9, "艉舵开关2断路器故障脱扣"},
{10, 4, 10, "FB预留断路器故障脱扣"},
{11, 4, 11, "TYZ预留断路器故障脱扣"},
{12, 4, 12, "预留断路器故障脱扣"},
{13, 4, 13, "艏部FT装置1-3 断路器故障脱扣"},
{14, 4, 14, "启闭机构断路器故障脱扣"},
{15, 4, 15, "桅杆舵机控制箱断路器故障脱扣"},
{16, 4, 16, "XCZ 断路器故障脱扣"},
{17, 4, 17, "艏舵控制箱断路器故障脱扣"},
{18, 4, 18, "敞水盖启动电缸断路器故障脱扣"},
{19, 4, 19, "锂电池组(仪表)断路器故障脱扣"},
{20, 4, 20, "艏部低压配电箱断路器故障脱扣"},
{21, 4, 21, "UNIT4仪表DC48V断路器故障脱扣"},
{22, 4, 22, "DC-DC1直流配电板断路器故障脱扣"},
{23, 4, 23, "预留断路器故障脱扣"},
{24, 4, 24, "预留断路器故障脱扣"},
{25, 4, 25, "应急锂电池组2断路器"},
{26, 4, 26, "UNIT1断路器故障脱扣"},
{27, 4, 27, "UNIT2断路器故障脱扣"},
{28, 4, 28, "UNIT3断路器故障脱扣"},
{29, 4, 29, "UNIT5断路器故障脱扣"},
{30, 4, 30, "艏部PZ装置断路器故障脱扣"},
{31, 4, 31, "预留断路器故障脱扣"},
{32, 4, 32, "预留断路器故障脱扣"},
{33, 4, 33, "应急锂电池组1断路器故障脱扣"},
{34, 4, 34, "动力母排绝缘低"},
{35, 4, 35, "A汇流排绝缘低"},
{36, 4, 36, "高压母线配电控制器仪表电源失电信号"},
{37, 4, 37, "高压母线配电控制器应急电源失电信号"},
{38, 4, 38, "高压汇流排A仪表电源失电信号"},
{39, 4, 39, "高压汇流排A应急电源失电信号"},
{40, 4, 40, "高压汇流排A仪表汇流排绝缘低"},
{41, 4, 41, "高压汇流排B仪表电源失电信号"},
{42, 4, 42, "高压汇流排B应急电源失电信号"},
{43, 4, 43, "高压汇流排B仪表汇流排绝缘低"},
{44, 4, 44, "仪表汇流排失电信号"},
{45, 4, 45, "仪表汇流排浸水报警"}
};
#endif // FAULTCODE_H